Sodium Molybdate 35%

Size:

Color:

Product Short Description: Corrosion inhibitor to protect metal surface in water syste.
Product Technical Specification:

Sodium Molybdate Specification :

Specification                Limit
Molecular Formula NA2MOO4.2H2O
CAS No 10102-40-6
Molecular Weight 241.95
Na2MoO4 x H2O  40.7 - 41.6% wt.
Na2MoO4 34.7 - 35.4% wt.

Molybdenum

16.2 - 16.5% wt.
pH 8.5 - 10.0
Specific gravity 1.377 - 1.386 (24C)
Mercury, as Hg <= 0.005%
Chloride (Cl)  ≤ 0.005%
Phosphate(PO4)  ≤ 0.05%
Sulfate ≤ 0.15%
Ammonium (NH4) ≤ 0.001%
Heavy Metal (Pb) ≤ 0.001%
Solubility in Water Soluble
 
Remarks:
Images: Alt



Pennstopsol 85 (Corrosion Inhibitor)

Size:

Color:

Product Short Description: short-stopper in styrenique rubber polymerization - oxygen scavenger (anticorrosion boiler water trea tment),
Product Technical Specification:
Remarks:
Images: Alt



Acid Corrosion Inhibitor RXSOL 213

Size:

Color:

Product Short Description: The addition of Acid corrosion Inhibitor RXSOL 213, inhibitors to hydrochloric acid solution provides maximum protection for equipment during,The removal of lime deposits or water scale from power plant boilers and piping systems and from evaporating equi
Product Technical Specification:
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Corrosion Inhibitor

Size:

Color:

Product Short Description: Corrosion inhibitor especially designed to inhibit the attack of hydrochloric acid and steel during industrial cleaning operations. It also inhibits acid attack on copper and brass. It does not contain arsenic, chlorinated hydrocarbons, or lead compounds.
Product Technical Specification:

Corrosion inhibitor that is used on metal equipment and surfaces that are acid cleaned to prevent the formation of rust.

Remarks:

Safety and Handling : 

Before handling the chemical products used in this process, the first aid and handling recommendations on the Material Safety Data Sheet for should be read, understood and followed. The industrial cleaning bath is strongly acid and can burn skin and eyes. Refer to the Material Safety Data Sheet for hydrochloric acid for recommendations for protective action.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Corrosion Inhibitor Carbon Dioxide and H2S

Size:

Color:

Product Short Description: To Prevent H2S Corrosion in distillation Columns overhead system. H2S Scavengers and Speaciality Chemicals to Reduce Hydrogen Sulfide Exposure
Product Technical Specification:

Hydrogen Sulfide Scavenger Manufacturer, supplier, Exporter. Product Code :  RXSOL-11-5014-210 is very effective  corrosive and Acidic GAS Remover. H2S Scavengers and Speaciality Chemicals to Reduce Hydrogen Sulfide Exposure from atmosphere.

Remarks:

H2S Scavengers and Speaciality Chemicals to Reduce Hydrogen Sulfide Exposure

Harmful and Colorless toxic gas, Toxic Odor like rotten egg in to the working environment is due to presence of good amount of Hydrogen Sulfide in the system.  

Hydrogen Sulfide is corrosive and Acidic GAS towards metal equipment practically observed that within 5 years can cause millions of dollars in damage to infrastructure.

RX Marine International offers a compleate line of water soluble and oil soluble hydrogen sulfide scavengers that can be applied via continous injection or through batch treatments.

HS Code : 3811900

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Corrosion Inhibitor

Size:

Color:

Product Short Description: Corrosion inhibitor especially designed to inhibit the attack of hydrochloric acid on iron and steel during industrial cleaning operations. It also inhibits acid attack on copper and brass. It does not contain arsenic, chlorinated hydrocarbons, or lead compounds.
Product Technical Specification:

Safety and Handling : 

Before handling the chemical products used in this process, the first aid and handling recommendations on the Material Safety Data Sheet for should be read, understood and followed. The industrial cleaning bath is strongly acid and can burn skin and eyes. Refer to the Material Safety Data Sheet for hydrochloric acid for recommendations for protective action.

Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Corrosion Inhibitor for Gas Compressor

Size:

Color:

Product Short Description: Corrosion Inhibitor for Gas Compressor
Product Technical Specification:

 

Test type ASTM method Corrosion Inhibitor
ISO VG   100
     
Water content, ppm D6304 20
Acid number TAN, mgKOH/g D974 1.32
Flash and fire point D92  
Flash point, °C   243
Ignition temperature, °С   268
Kinematic viscosity, cSt D445  
40°C   107.2
100°C   11.7
Viscosity index D2270 116
Pour point, °C D97 -37
Demulsibility D1401  
Oil-Water-Emulsion (time in minutes)   39-40-1 (10)
Volatility by NOACK D972  
Losses in % mass   2.9 
Copper Tape Corrosion D130  
100°C, 3 hours   1A
Corrosion D665  
A - in distilled water   Pass
B - in sea water   Pass

These products are also available in other viscosity grades and packaging. Additional test results are available upon request. 

 

 

Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Corrosion Inhibitor Closed Open Cooling Water System

Size:

Color:

Product Short Description: RXSOL-40-4028 creates an insoluble polymeric surface complex on copper and its alloys, and also reacts with copper in solution. RXSOL-40-4028 also works synergistically with other inhibitors to effectively control the corrosion of steel and aluminium in the system.
Product Technical Specification:
Remarks:
Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Acid corrosion Inhibitor RXSOL 213

Size:

Color:

Product Short Description: The addition of Acid corrosion Inhibitor RXSOL 213, inhibitors to hydrochloric acid solution provides maximum protection for equipment during,The removal of lime deposits or water scale from power plant boilers and piping systems and from evaporating equi
Product Technical Specification:

ACID inhibitor for HCl, Hydrochloric Acid. 

During Acidization corrosion prevention must required to protect metal surface from ACID effect. Inhibited hydrochloric acid  (HCl), HF doesn't damage metal surface. 
Remarks:

Acids and corrosive materials are used to enhance production and to stimulate reservoirs therefore special care is required to ensure that casing, tubing strings and downhole equipment are not damaged. Blend of ACID with Acid corrosion Inhibitor RXSOL 213 protect your downhole equipment and metal tubulars.

Images: Alt
Get MSDS
Get Technical Bulletin
Connect On Whats App



Corrosion Inhibitor for metal RUST Preventive

Size:

Color:

Product Short Description: Metal RUST Prevantiveprotective coating is thin, transparent, clear and slightly oily.
Product Technical Specification:

TYPICAL PHYSICAL AND CHEMICAL PROPERTIES:

Physical State : Liquid
Solubility in Water : Insoluble
Boiling Point : >190°F
Flash Point, COC : 190°F
Total Chlorine/Chloride, wt% : 0.00/0.00ppm
Appearance and Odor : Opaque/Chemical
Specific Gravity : 0.82
VOC Content (ASTM D2369) : 58%
pH Concentrate : NA
Total Sulfur, wt% : 0.00
 
Remarks:

How Rust Preventive Works?
Corrosion Inhibitor for metal RUST Preventive   rapidly displaces water from metal surfaces leaving a continuous polar protective film between the metal and water.

Images: Alt
stock-clearance.png